Troubleshooting
No power light
DALI controller is not
'seeing' Rail-DALI-DMX
DMX fixtures can only
be controlled by DALI
broadcast commands
The data light on
Rail-DALI-DMX is not
illuminated
Scene and Group
commands not working
DMX fixtures behaving
erratically
When I cycle power
to my DALI ballast,
it powers up at an
unexpected intensity
When I cycle power
to my DALI bus power
supply, the ballasts
go to unexpected
intensities
Artistic Licence
The Mould Making Workshop
Soby Mews
Bovey Tracey
TQ13 9JG
United Kingdom
Telephone
+44 (0) 20 8863 4515
Fax
+44 (0) 20 8426 0551
Email:
Web:
www.ArtisticLicence.com
Due to our policy of continuing product improvement specifications are subject to change without notice
1. Check that the DC power wires are connected to the correct
terminals and correct polarity.
2. Check power is switched on.
3. Disconnect all non-power cables. Switch off product and leave
for 20 minutes (this allows the thermal fuse to reset). Switch on.
If power light illuminates, it is likely that an external fault or wiring
error is causing the problem.
1. Product not powered on.
2. No DALI bus PSU present.
1. The Rail-DALI-DMX has not been commissioned. Use a DALI
tool such as DALI-Scope to achieve this.
1. Product not powered on.
2. No DALI bus PSU present.
3. DALI controller not connected.
1. Scene and Group commands are handled differently in Trigger
Mode. Try switching to Ballast mode (set DIP switch 6 OFF).
2. Scenes and Groups have not yet been programmed.
1. DMX cable not terminated at last fixture.
2. DMX cable is not suitable (must be data cable).
3. More than 32 DMX fixtures on the cable.
1. All DALI ballasts have a setting called 'Power On Level' which
defines their intensity after power cycle. The ballast will stay at
that intensity until Rail-DALI-DMX next refreshes it. Dali-Scope
can be used to both read and programme the Power On Level.
1. All DALI ballasts have a setting called 'System Failure Level'
which defines their intensity after a fault such as loss of DALI
bus power supply. The ballast will stay at that intensity until Rail-
DALI-DMX next refreshes it. Dali-Scope can be used to read the
ballast's System Failure Level. If power is not reinstated after 1s,
all the relevant DMX outputs will flash at full intensity.
Rail-DALI-DMX is CE compliant when installed
CE Compliance
in a shielded and earthed metal case
Customer support and knowledge base:
www.ArtisticLicence.com/support.html