ASI FS-0700 Manual de instalación
Navegue en línea o descargue pdf Manual de instalación para Dispensador ASI FS-0700. ASI FS-0700 6 páginas. Freestanding plastic laminate sanitizing station
FREESTANDING PLASTIC LAMINATE SANITIZING STATION INSTALLATION GUIDE (Pg 1 of 2)
INSTALLATION
1. Install spout and sensor housing with escutcheon flange, rubber washers and basin nut (supplied)
through 1" Dia [Ø25] mounting hole (provided) on stand top. See OM&IG for Model No 0390-HSD,
provided in box with dispenser
2. Install motor-pump module onto inside wall of stand at predrilled holes provided using two (2) № 8-32 x 1/2"
self-threading Phillips FH stainless steel screws (provided) through holes provided in mounting bracket.
Connect flex tubing (provided installed) from dispenser shank to fitting on top of pump/control housing with
firm press-in until hard stop.
3. Connect spout Com-cable plug into control unit inline cable connector.
Note: Com plug should be inser ted fully so that the white O-ring is not visible and a clicking sound is
heard. If Com plug is not connected properly, the motor will run continuously.
4. Connect clear supply flex tubing (provided attached to fitting on pump/control housing) to the 1.6 Gal [6 L]
tank (supplied) through the port in the cap so that tube end is just above bottom of tank. (see Figs. 2 and 2.a)
5. Install battery box (if so provided) on inside face of access door at predrilled screw holes with two (2) № 8 x
5/8" Type AB Phillips pan head stainless steel screws (provided). Load six (6) 'D'-size 1.5V cells (by others)
in battery carrier tray by removing two (2) Phillips screws and placing batteries according to polarity
indication. Re-install battery carrier tray and re-tighten the screws, plug battery cable jack into battery box
socket in cover handle and screw lock cover. Alternatively, plug AC Adapter (Model No 0390-ACA, if so
provided) into GFCI power outlet (by others) located within reach range of secured cable (straight length is
13.5 ft [4115] and will be reduced by securing wraps and allowable slack) on tank handle and plug connector
into mating inline power connector. (see Fig's. 1 and 3)
6. Remove the protective sticker covering the sensor.
7. Fill tank with correct sanitizer product (see 0390-HSD TDS and OM&IG) and prime system.
C L
2-3/4" [70]
17/32" [13]
1-7/64" [28]
12-3/4" [324]
Fig. 1
AMERICAN SPECIALTIES, INC.
441 Saw Mill River Road, Yonkers, NY 10701
(914) 476.9000 • (914) 476.0688
www.americanspecialties.com
CLEARANCE REQUIRED
12-5/64" [307] FOR DOOR
SWING ACCESS FOR
SERVICE
THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE
SPOUT MODULE SECURE
SHANK WITH BASIN NUT AND
WASHERS PROVIDED FULLY
CONNECT SUPPLY TUBE
AND COM CABLE PLUGS
POWER CABLE OBSERVE
BATTERY PLUG POLARITY
ENSURE NO KINKS
BATTERY PACK SECURE
CASE WITH SCREWS
PROVIDED LOAD WITH D
CELLS SECURE COVER
ADJUSTABLE LOCK KEEPER
KEEP SCREWS TIGHT TO
MAINTAIN DOOR SECURITY
MODEL №:
ISSUED:
REVISED:
[279]
[127]
Fig. 2
FS-0700
29 SEP 2020
7 OCT 2020
4-11/64" [106]
36-23/32"
[933]
11"
5"