AMCOL 6000P Manuel de l'opérateur - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} AMCOL 6000P. AMCOL 6000P 19 pages. Pneumatically controlled precision lubrication system
5 Operation
Before Getting Started
Ensure all hoses are connected to the appropriate fittings and are tightly secured.
•
Ensure all wiring connections to the solenoids are secure.
•
Refill reservoir if low or empty.
•
Securely connect an air source to the system air regulator. Check system pressure
•
(60 psi recommended).
Re-prime the system if liquid is not at the spray point.
•
Operating the System Actuation Solenoid
Observe 0 psi on the Dispersing Air Regulator when closed.
•
Observe no fluid output when the Pulse Rate Solenoid is closed.
•
Manually open the solenoid and set the Dispersing Air Pressure.
•
Manually actuate the solenoid and observe the fluid output. Modify injection volume
•
settings accordingly (clockwise to decrease, counterclockwise to increase).
Setting Injection Pulse Rate
The Pulse Frequency Generator can be modified through the dial on the face of the
•
PFG.
Pulse Frequency Generators should not be set less than ¼ of a turn, which is
•
equivalent to approximately 2 cycles per second.
Proper Operation
6000P PNEUMATICALLY CONTROLLED PRECISION LUBRICATION SYSTEM
System Timing
System timing can be seen to the left. This is the normal
operation when the system actuation solenoid is opened.
SV1 represents the Dispersing Air and is kept on during for the
full duration of the spray cycle (T1). SV2 represents the
Injection Pulse Rate set by the PFG, which should be
actuated according to the desired cycle rate (T2), up to 2
times per second.
Operator's Manual
P A G E | 6