POSSIBLE CAUSE
SYMPTOM: Burners do not come on.
Unit is not connected to gas service
Pilot is not burning
SYMPTOM: Pasta cooker does not boil water.
Unit may not have been operating long enough
Gas valve may be defective, not turning on
Too little gas pressure
SYMPTOM: General pasta cooker problems.
Temperature too low
!
WARNING
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
TROUBLESHOOTING GUIDE
Always disconnect the gas service before cleaning or
servicing the pasta cooker.
Pasta Cooker
SUGGESTED ACTION
Visually check if unit is plumbed to gas
Light pilot, check gas pressure/connection, see page 6
Unit preheats in about twenty to thirty minutes
Unit will require service
Call for authorized service
Check that knobs are set to ON position