Baumer GXAMW Manuel - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Baumer GXAMW. Baumer GXAMW 19 pages. Absolute encoder with powerlink interface
Également pour Baumer GXAMW : Manuel (41 pages), Manuel (26 pages), Manuel (24 pages), Manuel (19 pages)
5.3
SDO (Service Data Object)
Under TwinCAT there is access to the SDO objects under CoE - Online.
Please consider that every CoE access (mailbox communication) will shortly interrupt generation of encoder
input data for the time of mailbox communication. With short cycle times in Distributed Clocks Mode this may
imply that not in every Sync cycle a new position is detected.
Manual_EtherCAT_PoE_BIDE_EN.doc
8/19
Baumer IVO GmbH & Co. KG
11.11.10
Villingen-Schwenningen, Germany