Baumer Camera Link HXC20c Manuel de démarrage rapide

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Baumer Camera Link HXC20c. Baumer Camera Link HXC20c 2 pages.

Baumer Camera Link HXC20c Manuel de démarrage rapide
Quick Start Guide
HXC cameras – Release 2 (Camera Link
Latest software version and technical
documentation are available at:
www.baumer.com/vision/login
Safety
Conformity:
CE, FCC Part 15 Class B, RoHS
FCC – Class B device
N
: This equipment has been tested and found to
ote
comply with the limits for a Class B digital device, pursu-
ant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interfer-
ence in a residential environment. This equipment gener-
ates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructios,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occure in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off an
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the
receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician
for help.
Further Information
For further information on our products visit www.baumer.com
For technical issues, please contact our technical support:
[email protected]· Phone +49 (0)3528 4386-0 · Fax +49 (0)3528 4386-86
© Baumer Optronic GmbH · Badstrasse 30 · DE-01454 Radeberg, Germany
Technical data has been fully checked, but accuracy of printed cannot be guaranteed.
Subject to change without notice. Printed in Germany 06/14.
Product Specification
HXC cameras - Maximum Performance with CMOSIS sensors
Camera Link
®
Excellent image quality
Global shutter architecture for minimized motion blur
Low noise due to correlated double sampling (CDS)
HDR (High Dynamic Range)
Enhanced NIR sensitivity model available
Binning, subsampling and true partial scan function (ROI) for increased frame
rates
External synchronization via industrial compliant process interface (trigger / flash)
Integrated supplementary function for flexible integration
Integrated 256 MByte RAM for temporarily image data buffering
Two standard 26 pin Mini-CameraLink
Support for CameraLink
Baumer GAPI: Flexible, generic software interface for Windows
Camera Type
Monochrome
®
)
HXC20
HXC40
Color
HXC20c
HXC40c
Installation
Installation using
Camera Link
®
BASE:
Connect the camera using
an appropriate cable to the
framegrabber board on your
Safety instructions
PC using the lower sdr-26
Notice
jack on the camera side
See User´s Guide for the com-
If required, connect a strobe
plete safety instructions!
to the connector
Connect the camera to
Protect the sensor from dirt and
power supply
moisture.
Never open the camera housing.
Avoid camera contamination by
foreign objects.
Installation using
Environmental requirements:
Camera Link
MEDIUM /
®
Storage temp.
-10 °C ... +70 °C
FULL:
(14 °F...158 °F)
Operating temp.
+5 °C ... +60 °C
Connect the camera using
(41 °F...140 °F)
two appropriate cables to
Housing temp.
max. +65 °C
the framegrabber board on
(max. 149 °F)
your PC (this configuration
Humidity
10 % ... 90 %
requires the BASE and the
Non-condensing
FULL Camera Link
If required, connect a strobe
to the connector
Connect the camera to
power supply
v1.7
11054752
Full progressive scan CMOS camera
connectors
®
Base, Medium, Full and 10 tap configurations
®
Sensor
Full Frames
Resolution
Size
[max. fps]
2/3"
2048 x 1088
337
1"
2048 x 2048
180
2/3"
2048 x 1088
337
1"
2048 x 2048
180
Installation sample
1 - Framegrabber board; 2 - CameraLink
3 - Process interface cable; 4 - Power cable
line)
®
Installation sample
1 - Framegrabber board; 2 - CameraLink
3 - Process interface cable; 4 - Power cable
Dimensions HXC20/40 F-Mount
16 x M3 depth 6
52
Dimensions HXC20/40 C-Mount
UNC 1/4-20
16 x M3 depth 6
cable;
®
52
cable;
®
UNC 1/4-20
37
36
37,4