Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Amprobe TIC 300 PRO. Amprobe TIC 300 PRO 15 pages. Meet the new standard in non-contact, high voltage detection
Également pour Amprobe TIC 300 PRO : Manuel de l'utilisateur (18 pages), Manuel de démarrage rapide (4 pages)

Amprobe TIC 300 PRO Manuel de l'utilisateur
Find Quality Products Online at:
4. If voltage is present, the blue LEDs will blink and the
beeper will sound at an increased rate. Continuous
visual (blue LEDs) and audible indicators will increase
when the probe tip makes contact with or is very
close to the high voltage line.
TIC 300 PRO
HOT STICK
Fig. 2 Voltage detection in transmission lines
Locate breaks in insulated wire and heating
elements
(See Fig. 3)
1. Push the ON/OFF push button to turn the unit on.
2. Push the LOW range push button.
3. Make sure the wire or the heating element is energized.
4. Place the tip of the probe near the wire and start
tracing along it. When the fast or continuous beeping
stops, the point of the break or "open" is indicated.
7