ATIGO A3101 Manuel d'installation - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} ATIGO A3101. ATIGO A3101 11 pages. 2-wire video system
Également pour ATIGO A3101 : Manuel d'installation (15 pages), Manuel d'installation (7 pages)
Electric lock (internal power)
Electric lock controlled by door lock output.
The door lock output is limited to 12Vdc, and
a maximum current of 250mA.
Jumper setting JP-LK:
1-2
Normally closed mode
2-3
Normally open mode
Fail Locked
Fail Unlocked
Electric lock (external power)
1. The external power supply must be used
accordingly to lock specification.
2. The jumper must be taken off before
connecting.
3. Set lock type using touch keys A and B
(see module programming)
Fail Locked - Mode = 0 (default)
Fail Unlocked - Mode = 1