Spice rack
• If a spice rack is to be incorporated in front of the hood, a minimum
distance of 5 mm must be provided between the front edge of the
fume extractor hood and the spice rack wall (this air gap being
necessary for air circulation).
• The upper part of the spice rack rear wall should be detachable
(access for exhaust air hose or adjustment of furniture housing).
Installing the extractor hood in the wall unit - extraction version
(Recirculation version with charcoal filter)
• Fix the drilling template to the inside wall of the wall unit on the right
and left sides, and mark out and predrill Ø 2 mm mounting holes as
well as 2 x Ø 6 mm - 5 mm depth holes for the mounting claws
(installation aids).
• Fully withdraw the visor of the hood.
• Important: Detach and insert the grease filters only when the visor
is fully withdrawn.
Remove the grease filters. First remove the rear and then the front
grease filter.
• For 19 mm side walls, the spacer discs clipped in on the appliance
body must be taken out. Mount the hood with 4 screws. Fig. 11.
• Insert the hood in the furniture housing and engage both mounting
claws (installation aids) on the right and left sides in the side wall
of the wall unit and firmly hold the hood for further mounting.
Then fix the hood with the 4 screws supplied.
• Refit the grease filters. Push-in the visor.
Fig. 11