DSC PK5500 Manuel d'instructions d'installation - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} DSC PK5500. DSC PK5500 16 pages. Power series
Également pour DSC PK5500 : Manuel d'instruction (20 pages), Manuel d'instructions d'installation (9 pages), Manuel d'instructions d'installation (8 pages)
[074] Key Options
Default
ON
I____I
ON
I____I
ON
I____I
OFF
I____I
[076] First Keypad Options
Default
ON
I____I
ON
I____I
OFF
I____I
ON
I____I
OFF
I____I
ON
I____I
OFF
I____I
OFF
I____I
[077] Second Keypad Option
s
Default
ON
I____I
ON
I____I
OFF
I____I
ON
I____I
OFF
I____I
ON
I____I
ON
I____I
OFF
I____I
*The Low Temperature Warning is violated at 6°C (43°F) and restored at 9°C (48°F).
[080] PGM Terminal 1
Default: 01
1-14 Follow PGM Output Number, 15 Local PGM Pulse , 16 Local PGM Toggle
I_______I _______I
[082] Local PGM Output Pulse Activation Time
Default: 00
Minutes (Valid Range 00-99)
I_______I _______I
Default: 05
Seconds (Valid Range 00-99)
I_______I _______I
[101]-[108] Partition Labels
ex. For Partition 1 enter section [101], for Partition 2 enter section [102] etc.
Section
Partition
[101] to [108]
1 to 8
NOTE: Partition 1 Label is also used as the System Label.
Option
ON
1
[F]ire Key Enabled
2
For Future Use
3
[P]anic Key Enabled
4-8
For Future Use
Option
ON
1
Display Code when Programming
2
Local Clock Display ON
3
Local Clock Displays 24-hr Time
4
Auto Alarm Memory Scroll Enabled
5
Local Display of Temperature ON
6
Bypass Options prompt ON
7
For Future Use
8
Auto-Scroll Open Zones ON
Option
ON
1
Chime Enabled for Zone Openings
2
Chime Enabled for Zone Closings
3
5th Terminal is Keypad PGM Output
4
Language Selection Enabled
5
Power LED Enabled
6
Power LED indicates AC present
7
Alarms always Displayed When Armed
8
*Low Temperature Warning Enabled
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
OFF
[F]ire Key Disabled
[P]anic Key Disabled
OFF
Display "Xs" when Programming
Local Clock Display OFF
Local Clock Displays AM/PM
Auto Alarm Memory Scroll Disabled
Local Display of Temperature OFF
Bypass Options prompt OFF
Auto-Scroll Open Zones OFF
OFF
Chime Disabled for Zone Openings
Chime Disabled for Zone Closings
5th Terminal is Keypad Zone Input
Language Selection Disabled
Power LED Disabled
Power LED indicates AC absent
Alarms not Displayed When Armed
Low Temperature Warning Disabled
Label