ANSI ELE06FT-SKRebar Manuel d'instruction de l'utilisateur - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction de l'utilisateur pour {nom_de_la_catégorie} ANSI ELE06FT-SKRebar. ANSI ELE06FT-SKRebar 14 pages.
Leading Edge Clear Fall
Ÿ
The "arrest distance" experienced through testing, internally or externally is indeed 120", then clear fall requirement
Ÿ
would be 18ft, calculated and measured as follows:
120" -arrest distance measured from walking/working
Ÿ
surface to the hook attachment point to the test weight.
60" -Distance that needs to be added for the length of an
Ÿ
average worker measured from d-ring to feet.
36" -3ft safety factor to include D-ring slide/harness give
Ÿ
and buffer to ground below.
216"-(18ft) required clear fall as measured from the
Ÿ
walking/working surface to the nearest obstruction/ground
below.
Therefore, for all SRD-LE's, we need to make clear that "clear fall"
Ÿ
is measured from the walking/working surface to nearest
obstruction/ground below.
Standard SRL (When Used Vertically) Clear Fall Issue
Ÿ
Type A
Ÿ
24" – Maximum Arrest Distance
Ÿ
36" 3ft safety factor to include D-ring slide/harness give and buffer to ground below.
Ÿ
60" (5ft) required clear fall as measured from the walking/working surface to the nearest obstruction/ground below
Ÿ
Type B
Ÿ
54" – Maximum Arrest Distance
Ÿ
36" 3ft safety factor to include D-ring slide/harness give and buffer to ground below.
Ÿ
96" (7.5ft) required clear fall as measured from the walking/working surface to the nearest obstruction/ground
Ÿ
below
16.
PERSONAL FALL ARREST INFORMATION:
Personal Fall Arrest System (PFAS): Personal fall arrest systems used with this equipment must meet applicable state, federal, OSHA,
and ANSI requirements. A full body harness must be worn when this equipment is used as a component of a personal fall arrest system.
As required by OSHA, the personal fall arrest system must be capable of arresting the user's fall with a maximum arresting force of
1,800 lbs., and limit the free fall to six feet or less.
WARNING:
Do not alter or intentionally misuse this equipment. Consult with SAFE KEEPER when using this equipment incombination with
components or subsystems other than those described here in this manual and or other information. Use caution when
using this equipment around moving machinery, electrical and chemical hazards, and sharp edges.
7
Leading
Edge SRL
Sharp Edge