DSC ELECTRONICS DP-M Series Manuel de l'utilisateur - Page 16
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} DSC ELECTRONICS DP-M Series. DSC ELECTRONICS DP-M Series 16 pages. High power laboratorypowersupplies
DP-M Series User's Manual
Version 12.11.2021
Remark 1:
Supported baud rates: 1200; 2400; 4800; 9600; 14400; 19200; 38400; 43000; 57600; 76800; 115200; 128000
Due to the limitation of single register data range (0~65535), the baud rate needs to be divided by 10, that is, remove a
0 at the end and write it.
Specifications
Voltage
Line regulation
Current
Voltage
Load regulation
Current
Voltage
Ripple & Noise
(20Hz ... 20MHz)
Current
Voltage
Time drift
Current
Voltage
Temperature drift
Current
Voltage
Setting accuracy
Current
Voltage
Setting resolution
Current
Voltage
Readback accuracy
Current
Voltage
Readback resolution
Current
Transient response time
Protection
OVP setting range
OCP setting range
Digital interface
Analog interface (optional)
Cooling method
Operating environment
Storage environment
Input voltage
Input module
Accessories
≤0.1%FS rms
≤0.1%FS rms
≤0.1%FS rms
≤0.1%FS rms
≤0.3%FS +50mVrms
≤0.3%FS +10mArms
≤0.5%FS rms
≤1%FS rms
≤0.1%FS rms/℃
≤0.3%FS rms/℃
≤0.1% FS +20mV (≤100V)
≤0.1% FS +100mV (300V)
≤0.1% FS +300mV (≥600V)
≤0.3% FS +10mA
0.01V / 0.1V / 1V
0.001A / 0.01A / 0.1A / 1A
≤0.1% FS +20mV (≤100V)
≤0.1% FS +100mV (300V)
≤0.1% FS +300mV (≥600V)
≤0.3% FS +10mA
0.01V / 0.1V / 1V
0.001A / 0.01A / 0.1A / 1A
≤5ms (10% ... 90% load change)
OVP, OCP, OTP and short circuit protection
0.1V to 110% of rated voltage
0.1A to 110% of rated voltage
RS232 & RS485, ModBus-RTU (LAN Optional)
0-5V, 0-10V o 4-20mA interface for voltage/current control and feedback
Forced AIR
0℃ ... 40℃, 10% ... 80%RH
-20℃ ... 70℃, 10% ... 90%RH
≤6KW: 1φ2W, 230V±10% 50Hz/60Hz
>6KW: 3φ4W, 400V±10% 50Hz/60Hz
Power socket or terminal block
Operation manual: 1EA
DSC-Electronics Germany • Georgstraße 36 • 53111 Bonn
DSC-Electronics Germany • Georgstraße 36 • 53111 Bonn