AOR LA380 Manuel d'instruction - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} AOR LA380. AOR LA380 5 pages. Hi-q active loop aerial

6) Rotate the tuning dial on the loop element (clockwise and anticlockwise) until the receiver f s s i gna l
strength meter (S-meter) deflects to maximum and the incoming signal sounds clearest. If your receiver
does not have an S-meter, simply adjust for maximum received signal. Rotate the loop element until the
signal is strongest and any interfering signal is nulled.
It is advisable to locate the LA380 close to a window in
order to achieve the best possible reception.
In case your listening station is too far way from a
window, you have the possibility to use a (non-supplied)
BNC-BNC coaxial patch lead between the control box
and the loop.
The lead shouldn t be longer than 5m.
LA380 Specifications:
Frequency range
Impedance
Connector
Weight
Cable
Power
Supplied acc.
Specifications subject to change without notice or obligation.
10kHz-500MHz
50 Ohm
BNC
Approx.500g without accessories
1m RG58A/U (BNC plugs)
External DC 12V (9-15V), approx. 50mA.
LA380 Control box with loop
AC power supply
BNC-BNC Coaxial patch lead