Airwell AW-WHPMA10-91 Installation et configuration - Page 12
Parcourez en ligne ou téléchargez le pdf Installation et configuration pour {nom_de_la_catégorie} Airwell AW-WHPMA10-91. Airwell AW-WHPMA10-91 15 pages.
With the unit operating in Central Heating mode the mono bloc unit flow rate, can now be checked, to make sure the minimum
3. Scroll through and check the minimum flow rate for the unit fitted is been achieved adjust the flow setter
OPERATION PARAMETER
GAS BOILER
T1 LEAVING WATER TEMP.
WATER FLOW
HEAT PUMP CAPACTIY
POWER CONSUM.
Ta ROOM TEMP
ADDRESS
Error
code
C7
Transducer module temperature too high protect
E0
Water flow failure (E8 appears 3 times)
E1
Phase sequence error (for 3 phase models)
E2
Communication error between the main control board of hydraulic module and user interface
E3
Backup electric heater exchanger water outlet temperature sensor T1 error
E4
Domestic hot water tank temperature sensor T5 error
E5
Air side heat exchanger refrigerant outlet temperature sensor T3 error
E6
Outdoor ambient temperature sensor T4 error
E7
Balance tank sensor Tbt1 error
E8
Water flow failure within 3 times
E9
Suction pipe temperature sensor Th error
EA
Discharge pipe temperature sensor Tp error
Eb
Solar board sensor Tsolar error
Ec
Balance tank sensor Tbt2 error
Ed
Water side heat exchanger water inlet temperature sensor Twin error
W: www.aukdistribution.com
Final Operational Checks
flow rate is been achieved.
1. Enter SERVICEMAN menu as described in the previous sections.
2. Select Operation Parameters.
#01
OFF
AW-WHPMA04-91
AW-WHPMA06-91
35°C
AW-WHPMA08-91
1.72m
/h
3
AW-WHPMA10-91
11.52kW
AW-WHPMA12-91
AW-WHPMA14-91
1000kWh
AW-WHPMA16-91
AW-WHPMA12-91 3ph
25°C
AW-WHPMA14-91 3ph
AW-WHPMA16-91 3ph
3/9
*Please be aware if, only the minimum flow rate is achieved through the unit the unit
will not function to its full output.
Fault Codes
T: 0191 516 6553
if required.
Unit
Minimum Flow
Rate
6.64 Lpm*
6.64 Lpm*
6.64 Lpm*
6.64 Lpm*
11.62 Lpm*
11.62 Lpm*
11.62 Lpm*
11.62 Lpm*
11.62 Lpm*
11.62Lpm*
Maximum Flow
Rate
0.40 m³h*
14.16 Lpm
0.85 m³h
0.40 m³h*
20.82 Lpm
1.25 m³h
0.40 m³h*
27.48 Lpm
1.65 m³h
0.40 m³h*
33.32 Lpm
2.0 m³h
0.70 m³h*
41.65 Lpm
2.50 m³h
0.70 m³h*
45.81 Lpm
2.75 m³h
0.70 m³h*
49.98 Lpm
3.0 m³h
0.70 m³h*
41.81 Lpm
2.50 m³h
0.70 m³h*
45.81 Lpm
2.75 m³h
0.70 m³h*
49.98 Lpm
3.0 m³h