12.
Pressure begins when the gun trigger is squeezed.
KEEP THE MACHINE OUT OF MOISTURE LADEN
ATMOSPHERES
G.

Stopping the machine

1.
Allow machine to run for 1 minute without load to
cool before stopping.
2.
Select the red off button on control panel.
3.
This blaster is fitted with an emergency stop button.
After activation, turn engine key to off and reset
stop button by rotating until it pops out.
4.
Switch the Power Off on the control panel.
5.
Battery isolator can be locked off to prevent blaster
from operating.
6.
Turn off water supply.
7.
Pull gun trigger to release all pressure in the system,
then LOCK THE TRIGGER.
8.
Hoses may now be disconnected from the machine.
Failure to release pressure before disconnecting the
hose quick coupler will result in the quick coupler o-
ring seal blowing out. This o-ring must be replaced
before operating machine.
CARE AND MAINTENANCE:
AFTER EACH USE
If cleaning agents have been mixed with the
incoming water, it is essential to flush the
machine with clean water after use.
If there is a danger of freezing anti-freeze should be mixed
with the flush water or the machine must be completely
drained.
After the final flush stop the machine. DO NOT allow the
machine to idle for more than 15 seconds.
particularly important when there is a danger of freezing.
Do not run for longer without water supply.
DO NOT RUN EXCESSIVE BY-PASS
SWITCH MACHINE OFF WITHIN TWO MINUTES OF
CEASING OPERATION AS EXCESSIVE BY-PASS CAN CAUSE
HEAT BUILD UP IN PUMP AND SUBSEQUENT DAMAGE.
EXCESSIVE BY PASS RUNNING VOIDS WARRANTY!!
WORK SMART ... STAY SAFE
8
AUSSIE SAFE BLASTING
This is
| Aussie Raptor (Class B) ... Operator's Instruction Manual
STORAGE
Store the washer in an upright position, preferably drained
of water if there is a danger of freezing (or fill with anti-
freeze).
PUMP CRANKCASE LUBRICATION
Proper pressure washer pump crankcase lubrication will
help extend the working life of the machine. Follow these
important guidelines. We recommend keeping a simple
service log book.
Change pump oil every 40 hours of use high quality
oil. (SAE 75W-90)
Pump oil level can be checked with the dip stick
under the breather cap or by viewing the oil sight
gauge where fitted. The oil level is correct if level is
in the centre of the gauge. If oil level is low, fill to
correct level with recommended oil (SAE 75W-90).
DO NOT OVERFILL CRANKCASE!
Replace oil in gearbox (separate chamber) with SAE
90 gear oil every three months.
PREVENTATIVE MAINTENANCE
Rinse filter in supply hose connection regularly.
Use correct size nozzles for machine and replace
when worn, check serial tag for correct size.
Drain water from pressure hoses, gun/lance
assembly and accessories after use.
Protect pump from freezing. Failure to remove
water from the pump in freezing temperatures will
result in damaged pump manifold.
Use ONLY injector of the size and type designed for
this model.
DO NOT tamper with unloader valve adjustment or
alter engine speed.
DO NOT siphon chemicals through the pump, it is
designed for water only.
Incoming water supply must not exceed 60°C,
otherwise pumps seal damage could result
Follow engine manufactures guidelines for engine
maintenance. (see engine manual)
WARNING:
CHECK NOZZLES AND REPLACE IF WORN
If pressure drops off, check nozzle for wear.
Nozzles should be replaced every 40 hours. Using
the machine with the incorrect nozzle size or worn
nozzle will void warranty and can be dangerous to
the operator.
August 2019