Automationdirect.com Productivity 2000 P2-SCM Manuel

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Automationdirect.com Productivity 2000 P2-SCM. Automationdirect.com Productivity 2000 P2-SCM 8 pages. Serial communications

Automationdirect.com Productivity 2000 P2-SCM Manuel
General Specifications
Module Type
Intelligent
Modules per Base
15 maximum*
I/O Points Used
None, mapped directly to tags in CPU
Field Wiring Connector
3 - RJ12, 1 - 4 Position Terminal Block
Operating Temperature
0º to 60ºC (32º to 140ºF)
Storage Temperature
-20º to 70ºC (-4º to 158ºF)
Humidity
5 to 95% (non-condensing)
Environmental Air
No corrosive gases permitted
Vibration
IEC 60068-2-6 (Test Fc)
Shock
IEC 60068-2-27 (Test Ea)
Field to Logic Side Isolation
None
Insulation Resistance
No isolation
UL508 File E139594, Canada & USA
Agency Approvals
CE (EN61131-2007)
Module Location
Any slot in any base in a Productivity2000 System
Weight
90g (3.2 oz)
* Note: For complete system limits, please refer to the "Hardware and
Communication Limits" table in the Prodctivity Suite Help file, "Automatic Hardware
Configuration" topic (P050).
Document Name
Edition/Revision
P2-SCM-DS
1st Ed.
Copyright 2015, AutomationDirect.com Incorporated/All Rights Reserved Worldwide
Sales 800-633-0405
Date
3/6/2015
Warranty: Thirty-day money-back guarantee. Two-year limited replacement.
(See www.productivity2000.com for details).
2000
P2-SCM
Serial Communications
The P2-SCM Serial Communications Module
provides three RS-232 ports and one RS-485
port for Modbus master/slave networking or to
serial devices using ASCII or custom
communication protocols. Port 1 Powers a
C-More Micro when using an RJ-12 connector.
General Specifications . . . . . . . . . . . . . . . . . . . . . . 1
SCM Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Module Installation Procedure . . . . . . . . . . . . . . . . . 2
P2-SCM Configuration Options . . . . . . . . . . . . . . . . 3
RS-232 Port Specifications . . . . . . . . . . . . . . . . . . . 4
RS-485 Port Specifications . . . . . . . . . . . . . . . . . . . 4
Port 1 (RS-232) Specifications . . . . . . . . . . . . . . . . 5
Port 2 & 3 (RS-232) Specifications . . . . . . . . . . . . . 5
Port 4 (RS-485) Specifications . . . . . . . . . . . . . . . . 6
Diagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Removable Terminal Block Specifications. . . . . . . . 8
Cable Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hot Swap Information . . . . . . . . . . . . . . . . . . . . . . . 8
www.productivity2000.com
1