1. Lock position: The DC motor has a built-in safety against obstruction during operation. The motor will get locked
operation and disconnect power after 30 seconds if interruption occurs. Please remove obstacles before re-set.
2. Over 38W protection: When the receiver detects motor power consumption which is greater than 38W, the receiver's
power will stop and operation will be immediately discontinued. Turn the receiver power on after 5 seconds.
3. "D" and "ON" dip switch: The "D" selection is the light dimmable selection and is to be used with all bulbs except for
CFL bulbs. The "ON" selection is For CFL bulbs.
Speed settings for warm or cold weather depend on factors such as room size, ceiling height and number of fans.
NOTE: To change the direction of the rotation of the blades the fan must be in operation mode.
Warm Weather (forward)
A DOWNWARD airflow creates a cooling effect as shown in Figure 24. This allows you to set your air conditioner on a
warmer setting without affecting your comfort.
Cool Weather (Reverse)
An UPWARD airflow moves warmer air off the ceiling area as shown in Figure 25. This allows you to set your heating unit
on a cooler setting without affecting your comfort.
SUMMER OPERATION
WINTER OPERATION
(
)
(
)
COUNTERCLOCKWISE DIRECTION
CLOCKWISE DIRECTIO
N
FIG. 24
FIG. 25
14