Autonics BC15-LTD-C Manuel - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Autonics BC15-LTD-C. Autonics BC15-LTD-C 7 pages. Color mark sensor

Autonics BC15-LTD-C Manuel

Indicator Display

Status
Stable match
Unstable match
Normal
operation
Unstable mismatch
Stable mismatch
Fine
Sensitivity
setting
Normal
(C mode)
Rough
Fine
Sensitivity
setting
Normal
(C+I
mode)
Rough
Teaching standby
Normal teaching
Teaching
Excess light intensity
setting
Teaching
Insufficient light intensity
error
Fluctuating light intensity
ON
Timer
setting
OFF
Overcurrent input
※ Indicator status
ON
Flashing (every 0.5 sec)

Troubleshooting

Problem
Cause
Power supply
Will not operate
Connection error
Excess light intensity alarm during teaching, output
chattering
Converter external light interference
Will not operate
occasionally
Contamination of sensor cover
Connector error
Other error
-
Operation indicator
Stability indicator
(red LED)
(green LED)
OFF
Flashing alternately (every 0.5 sec)
Troubleshooting
Supply power within rated specifications
Check the cable connections.
Install the sensor at a 10 to 20 degree angle.
(when sensing metal or glossy objects)
Install a visor on the sensor or install the unit away
from the external light source.
Remove the substance using a soft brush and reset
the sensitivity.
Check connector assembly.
Check the display status of the indicators.
Color Mark Sensor
Timer indicator
Teaching indicator
(orange LED)
(full color LED)
Timer ON
(teaching color)
(red)
(green)
(blue)
(red)
(green)
(blue)
(orange)
(teaching color)
(green)
(red)
(blue)
(teaching color)
(teaching color)
SENSORS
Timer OFF
CONTROLLERS
MOTION DEVICES
SOFTWARE
(A)
Photoelectric
Sensors
(B)
Fiber Optic
Sensors
(C)
LiDAR
(D)
Door/Area
Sensors
(E)
Vision
Sensors
(F)
Proximity
Sensors
(G)
Pressure
Sensors
(H)
Rotary
Encoders
(I)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
A-135