BD Series

▣ Installation Precautions

For stable measurement, mount the sensor head by referring to the below items.
◎ Moving object measurement
1. Object with material / color difference
2. Rotating object
3. Object with step
◎ Narrow area or concave object
◎ Wall mounting
◎ Black object
E-14
When measuring black object with low reflectance the amount of light received
decreases, install the sensor head closely to the object.
Install the emitter and receiver in parallel to the material or
color boundary of the object.
Install the receiver and the rotating shaft in parallel to minimize
the influence of fluctuations and position deviations.
Install the emitter and receiver vertically to the line between crest and
valley of the object.
Install the sensor head where the reflected laser beam does not
blocked toward the receiver part.
Install the sensor head where the reflected laser beam from the wall
does not enter the receiver part.
If the color of wall is black with low reflectivity and no gloss, the error
can be minimized.