Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
BF4
-
❶ Light source
R: Red LED
G: Green LED
❸ Features
No mark: Standard type
E: External synchronization input type
R: Remote sensitivity setting type
Product Components
• Product
• Bracket
Sold Separately
• Fiber optic units
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
12
2-Ø2.4
16.4
■ Bracket
35
2
14
27
Unit Descriptions
06
01
02
03
04
05
Standard type,
External
Remote sensitivity
synchronization
setting type
input type
Supporting Functions of Each Model
• For more detailed information on functions and settings, refer to the manual.
Standard type
Sensitivity setting
by the button
Remote sensitivity setting
-
Sensitivity setting output
-
(Answer back)
Operation mode of the timer
(OFF Delay 40 ms fixed)
Mutual interference
prevention
Self-diagnosis output
External synchronization
-
input
Emitter OFF function
-
❷ Control output
No mark: NPN open collector output
P: PNP open collector output
• Instruction manual
• Bolt / Nut × 2
62
Ø4, 2m
36.5
12
1
16
R1.6
01. Operation indicator (red)
02. Stability indicator (green)
03. Setting switch for the mode
- SET: function setting
- LOCK: lock mode
04. Setting switch for the timer /
external synchronization
- NON: not used,
OFD: OFF Delay mode
- GATE: gate synchronization,
TRIG: trigger synchronization
05. Sensitivity setting button
06. Lever lock
It is used to fix the fiber optic unit.
External
Remote sensitivity
synchronization
setting type
input type
-
-
-
-
-
Connections
• Connect the diode at the external terminal for inductive load.
• For wiring, refer to the table below.
Function
External
Color
Standard type
synchronization
input type
Brown
+V
Control output
Black
White
Self-diagnosis output
Blue
0 V
External synchronization
Pink
-
input
Orange
-
Emitter OFF input
01) Signal condition
High: 4.5-30 VDCᜡ or Open, Low: 0-1 VDCᜡ
■ Standard type
Brown
LOAD
Black
LOAD
Max. 100 mA
NPN
White
Max. 50 mA
Blue
■ External synchronization input type /
Remote sensitivity setting type
Brown
Pink
LOAD
Orange
NPN
Black
Max. 100 mA
White
Max. 50 mA
Blue
Circuit
■ Standard type
• NPN open collector output
LOAD
LOAD
Max. 100 mA
Max. 50 mA
■ External synchronization input type /
Remote sensitivity setting type
LOAD
Max. 100 mA
Remote sensitivity
setting type
01)
01)
Remote sensitivity
setting ON
Remote sensitivity
setting OFF
Brown
Max. 100 mA
Black
PNP
LOAD
Max. 50 mA
White
LOAD
Blue
LOAD
• PNP open collector output
Max. 100 mA
Max. 50 mA
LOAD
LOAD
LOAD
Max. 50 mA