DBI SALA Sayfline 7603180 Manuel d'instruction de l'utilisateur - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction de l'utilisateur pour {nom_de_la_catégorie} DBI SALA Sayfline 7603180. DBI SALA Sayfline 7603180 17 pages.

sleeve(s) onto the lifeline before terminating the other
end of the cable to the anchor.
Step 4.
If additional intermediate brackets are purchased,
slide all of the cable guides from the brackets onto
the cable before installing the cable.
Step 5.
The intermediate brackets are composed of three
parts: two side plates and a cable guide. Each of the
plates is stamped with the letter "A" or "B". See
Figure 10. To assemble a bracket, start by placing a
cable guide into Part A at the appropriate angle as
determined in Step 2. Then slide Part B onto the
cable guide at the same angle and nestle Part B
into Part A. Place the assembled bracket at its
designated anchor point and anchor it by placing
the user supplied bolt through a flat washer and
then though the mated holes in the bracket and
into the anchor point. The bolt may be installed
through the anchor and into the bracket if
preferred, but the washer must remain inside the
bracket, between the bracket and the bolt head
or nut. Torque the anchor hardware to 55 ft./lbs.
Step 6.
Before terminating the second end of the
horizontal lifeline, unthread the turnbuckle on the
first end so that only four threads are visible
inside the turnbuckle body. This will allow for
maximum tensioning of the system after
anchoring the second end. Install all of the
Sayflink sleeves onto the cable before terminating the second end.
Step 7.
To terminate the second end of the cable to its anchor, attach the shackles to the anchor and Zorbit as
described in Step 3. Then attach the thimble and connecting hardware to the Zorbit. See Figure 11.
Slide the lifeline through the thimble. Remove excess slack by pulling the wire rope through the thimble
and cable clip. Maintain tension while torquing the cable clip nut and the thimble clip nut to the values
specified in Figure 11. Tension the wire rope by turning the turnbuckle at the other end of the installation.
The unrestrained turnbuckle jaw end must be prevented from turning to prevent twisting the wire rope.
The wire rope must be tensioned until the sag on the system at mid-span, between intermediate
brackets, is two inches or less, with no weight on the wire rope.
Sayfline Wire Rope HLL System End Termination
Cable Clip
Torque to 45 ft/lbs
Figure 11 - Thimble/Cable Clip End Termination
Figure 9 - Cable Termination
Figure 10 - Bracket Assembly
Part A
Part B
Cable Guide
Thimble/Cable Clip
Torque to 40 ft/lbs
7
Shackles
Zorbit Shock
Absorber
Turnbuckle