Aire-Flo 42 Manuel d'instructions d'installation

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Aire-Flo 42. Aire-Flo 42 18 pages. 14 seer

Aire-Flo 42 Manuel d'instructions d'installation

INSTALLATION INSTRUCTIONS

THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause personal injury, loss of life, or
damage to property.
Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.
STEP 1 -- SETTING THE UNIT -- Clearances
See NOTES
See
NOTES
See NOTES
NOTICE: Specific applications may require adjustment of the listed installation clearances to provide protection for
the unit from physical damage or to avoid conditions which limit operating efficiency. (Example: Snow and ice falling
on the top of the unit or installation under a deck with minimum clearances, causing recirculation of air.)
STEP 1 -- SETTING THE UNIT —
Unit Placement
CAUTION
Before attempting to perform any service or mainte­
nance, turn the electrical power to unit OFF at disconnect
switch.
AIRE-FLO 14 SEER
AIR CONDITIONER UNITS
See
NOTES
CONTROL
BOX
GENERAL
This outdoor air conditioner with all-aluminum coil is
designed for use with HFC-410A refrigerant only. This unit
must be installed with an approved indoor air handler or
coil.
IMPORTANT: Special procedures are required for
cleaning the aluminum coil in this unit. See page 16 in this
instruction for information.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.
NOTES -
Service clearance of 30 in. (762 mm) must be maintained on one of
the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in. (914 mm).
Clearance to one of the remaining two sides may be 12 in. (305
mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
FIGURE 1
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take care
while handling this equipment and use protective cloth­
ing.
Page 1
CAUTION