Function
▣
Teaching
- This function is to familiarize the space which is set by the
monitoring zone width (W) and height (H) in advance.
- Objects in the space at moment of teaching are not regarded
as obstacles.
- When the environment is changed or some objects are
removed or added in the space, newly operate teaching.
- Teaching takes 35 seconds.
※ For re-install the unit teaching already at no teaching required
area, initial the unit. Do not re-teaching it.
※ Operate teaching in the environment free from snow, rain,
fog, hail, or mutual interference of another laser scanner.
Password
- When entering the
user who entered the right password changes the parameter
settings of sensor position, monitoring zone width (W), height
(H), etc.
- When setting password, the password function is activated.
※Password setting range: 0000 to 9999
※ When losing the set password, re-supply the power and set
the password again in 10 minutes.
※ Please use the password function for preventing mutual
interference of several units or malfunction.
※ If any key is not entered for 1 sec after entering the
the laser scanner is scanning mode.
▣ Troubleshooting
※Check the normal operation status of LSE-4A5R2 periodically.
Error
Power indicator (green)
OFF
Error indicator (orange)
flashing
Relay output is ON without
objects within teaching area
Laser scanner does not
react for remote control
operation.
After pressing the
of remote control, the setting
is not available.
atLidar (PC program) and
the laser scanner does not
connected.
key of the remote control, only the
Causes
Supply the power voltage.
Wrong polarity connection of power supply
Voltage error
Temperature error
Inside error
Detection by external environment (snow,
rain, or hail, etc.)
There is the equipment which generates
strong magnetic force or high frequency
noise (motor, generator, or power cable,
etc.) near the laser scanner.
The batteries' life cycle of the remote control
is over.
Wrong direction control of the remote
control
key
Password incorrect.
LAN connector connection error
IP address is not same.
IP address of the laser scanner and wireless
router is same.
Factory default initialization
- The laser scanner's settings: sensor position, monitoring zone
width (W), height (H), activated channel(s), etc. and IP, except
password initializes as facotry default.
IP initialization
- The laser scanner's IP address initializes as factory default.
Setting initialization
- The laser scanner's settings: sensor position, monitoring zone
width (W), height (H), activated channel(s), etc. except IP as
factory default.
key,
Troubleshooting
Check the rated power supply.
Check the Connection diagram when wiring the unit.
Use the unit within the rated voltage.
Use the unit within the specified ambient temperature.
Contact the seller.
Change the settings: sensitivity level, scanning target size,
monitoring time.
Install the laser scanner away from the equipment which
generates strong magnetic force or high frequency noise.
Change the batteries.
Operate the remote control towards the near laser scanner.
Turn OFF the power and re-supply the power, the password
is available to reset.
Contact the seller.
Check the PC and LAN connector connection part.
Check the IP address of the laser scanner and the user PC.
Set the wireless network (Wifi) to "Disable" in the network
settings of the Windows operating system.