Autool BT160 Manuel de l'utilisateur - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Autool BT160. Autool BT160 10 pages. Automotive electric system tester

Autool BT160 Manuel de l'utilisateur
«
There are probably sparks on probe tip during it is used.
DO NOT operate it in area with combustible gas, dust and
explosive conditions.
«
Check case and leads prior to using it. DO NOT use it
when cracks or damage is visible.
«
Be careful of the sharp probe tip during using or putting
away this tool. Keep out of reach of children
«
DO NOT attempt to open this tool, no serviceable parts
are inside. Opening it voids the warranty. All repairs should
only be performed by authorized dealer.

◆ Specification

Operation Voltage:6-24V DC
Overload Protection:10A
Lead Length:approximately 4M (13F)
◆ Description
Red LED: Positive voltage
supplied or indicated.
Green LED: Negative voltage
supplied or indicated.
Power Switch:
Press button to "-" side to output
positive voltage;
Press button to "=" side to output
negative voltage.
探针
Probe Tip
指示灯
LED Indicator
Power Switch
Red Clip
正极夹子
Black Clip
负极夹子
按键
Auxiliary
Ground
Lead