INSTRUCTION MANUAL

installation

sensor asseMBlY
1. If you are using the APCEPH1SK
sampling assembly, refer to the
instructions to install the sensors.
2. If you are not using the APCEPH1SK
sampling assembly, connect the probe
 
cables and then secure the probes in
the water to be measured.
 
Using the sampling assembly
Not using the sampling assembly
circulatinG puMp
1. A circulating pump provides a constant
flow of water to the sensors. The
circulating pump should be connected
to a constant power source.
Note: For aquarium use, a filter pump
head can be used to provide constant
water flow to the sensor assembly.
2. Connect a piece of tubing from
your circulating pump to one of
the inlets on the sensor assembly
(water can flow in either direction
through the sampling assembly). The
sensor assembly has been designed
to mount on the side of the water
tank / reservoir or a wall. The return
side of the sensor assembly must be
positioned so that the water will go
back into the water tank / reservoir. A
second piece of tubing can be used.
Note: The inlet filter on the submersible
pump should be cleaned frequently to
ensure the sensor probes do not become
dirty.
DosinG puMp
1. The dosing pump outlet tubing
must be positioned to allow the
pH adjustment liquid to enter the
water tank/reservoir. The pump is
self-priming and will transfer the
pH adjustment liquid from the pH
adjustment bottle into the water tank/
 
reservoir. Select a suitable location to
secure the dosing pump.
Note: Ensure you are using the correct pH
adjustment (acid or alkali) based on your
needs.
2. Once the dosing pump is secured, and
the small tubing is securely connected
to the pump's inlet and outlet, cut the
tubing to the correct length. The inlet
side of the tubing must reach into the
bottom of the pH adjustment bottle,
 
the outlet side is placed into the water
tank / reservoir.
3. The peristaltic dosing
pump inlet must be
connected to the user's
pH liquid adjustment
bottle. The simplest
way to do this is to drill
or punch a small hole in
the screw cap of your
pH adjustment bottle.
Then insert the small
diameter chemically
resistant tubing though the cap to the
bottom of the pH adjustment bottle.
4. To "prime" the pump, plug the pump's
power supply cable into a source of
power and to the dosing pump. The
pump will operate and slowly the pH
adjustment liquid will be drawn up to
the pump and out of the outlet tubing.
Disconnect the dosing pump.
 
 
5