Bristol H23A303ABH Manuel d'installation et d'entretien - Page 17

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'entretien pour {nom_de_la_catégorie} Bristol H23A303ABH. Bristol H23A303ABH 18 pages. Refrigeration/air conditioning/heat pump compressors

Bristol H23A303ABH Manuel d'installation et d'entretien
COMPRESSOR MODEL NUMBER SYSTEM
H
2
9
B
18U
A
B
C
A
Mounting Feet Dim............. A = 7.5 x 7.5
.......................................... E = 9.5 x 9.5
.......................................... J = 7.5 x 22.5
Electrical Characteristics.... A = 115-1-60
.......................................... B = 230-1-60
.......................................... C = 230/208-1-60
.......................................... D = 230/208-3-60 (220/200-3-50)
.......................................... E = 460-3-60 (380/415-3-50)
.......................................... F = 575-3-60 (500-3-50)
.......................................... G = 200-1-60
.......................................... H = 265-1-60 (220/240-1-50)
.......................................... J = 230/208-1-50
.......................................... K = 220/240-1-50
.......................................... L = 230/200-3-60 (220/200-3-50)
Motor Protector .................. B = Internal Line Break
.......................................... P = Pilot Duty – Solid State
.......................................... R = Pilot Duty – Solid State (2
.......................................... T = Pilot Duty – Internal Thermostat and External Sensing Elements
Motor Type......................... A = PSC Permanent Split Capacitor
..........................................
.......................................... B = CSR Capacitor Start/Cap. Run
.......................................... C = RSCR Resistance Start/Cap. Run
.......................................... D = AI 3-Phase – Across the Line
.......................................... E = CSIR Cap. Start/Induction Run
Capacity............................. 193 = 19,000 BTU/Hr., 244 = 240,000 BTU/Hr. when 5-7 digits are numerical
.......................................... 19Q = 19+3-0's in "Quiet Version" – 19,000 BTU/Hr. "Quiet"
Family ................................ A = Model A Reciprocating
.......................................... B = Model B Reciprocating
.......................................... C = Scroll (<42K)
.......................................... D = Dual Compressor Application
.......................................... G = Model G Reciprocating
Generation ......................... B = Second Generation – No PRV (except G series)
.......................................... D = Dual Compressor Application (Single and Interconnected)
.......................................... E = High Efficiency
.......................................... M = Alternate Pressure Relief Valve
.......................................... N = No Pressure Relief Valve (except G series)
.......................................... O = Basic Standard Model
.......................................... P = Basic Standard Model – Upgrade Plus
.......................................... 1 = Second Generation – Basic Standard Model
Type of Refrigerant ............ 2 = R22
.......................................... 4 = R134a
.......................................... 8 = R410A
Refrigeration Application .... H = High Temperature
.......................................... M = Medium Temperature
.......................................... L = Low Temperature
B = 4.8 x 8.0
C = 8.4 x 9.8
F = 10.5 x 10.5 H = 7.5 x 21.5
X = 8.8 x 6.1
M = 220/200-3-50
N = 380/415-3-50
P = 240/200-1-50
T = 208-1-60
U = 220/380-3-60
V = 460/380-3-60 (380/415-3-50)
W = 380/460-3-60
X = 380-3-60
Y = 230/208-3-60 (No 50 Hz)
nd
Generation)
F = PWS 3-Phase –
Part Winding Start
G = 3-Phase 2/4-Pole (2-Speed)
J = 1-Phase 2/4-Pole (2-Speed)
K = 3-Phase – Dual Voltage
L = 3-Phase – WYE DELTA
J = Benchmark Reciprocating (16 – 43K)
R = Scroll (>42K)
S = Single Cylinder Series
T = Two Cylinder Series
6 = R404A (SUVA HP62)
7 = R407C (SUVA AC9000 or KLEA 66)
S = High Temperature (One Capacity / 1,2,3 or 4 cylinder) – Half/Single
T = High Temperature (Two Capacities / 2 or 4 cylinder) – Twin/Single
Page 17
Family
Reciprocating
Compressors Serial
Serial Number System
Number System
Example: S3702K00001
S
37
02
K
First 5 digits are the Julian
00001
date of Manufacture:
Year Manufactured
Mfg. Location
02
2
108
0 or 2 = Bristol
02 = 2002
108 = April 18th
2 = Third Generation – Basic Standard Model
3 = Fourth Generation – Basic Standard Model
4 = Basic Standard Model – Improved Sound
5 = Inertia Series – Standard Model
6 = Inertia Series – High Efficiency Model
7 = Inertia Series – Second Generation High Efficiency Model
8 = Fifth Generation – Basic Standard Model Upgrade
9 = Sixth Generation – Basic Standard Model Upgrade
Scroll Compressors
= Scroll Technologies
= Production Week
= Year
= State (Arkansas)
= Sequence # of
Units Built During Week
Daily Unit Manufactured
00235
th
00235 = 235
unit of the day