INSTALLING OR REPLACING THE ULTRAVIOLET LAMPS
Steps for Replacing the Ultraviolet Lamps:
1. READ THE WARNINGS ABOVE.
2. If the unit is plugged into an AC outlet, simply unplug it before servicing the UV
lamps.
3. Open the Display Panel door. The Display Panel door is connected to a kill switch
that disables power inside the unit when the door is opened.
4. The unit contains 2 UV lamps. The base of the UV lamps (white in color) are visible
on the left side of the enclosure. Attached to each lamp base is a white socket with
wires leading to the power supplies that are housed to the right (separately
enclosed). Pull the lamp socket off the UV lamp base.
5. Each lamp base is held in a cavity by two swivel clamps. Simply swivel them out of
the way. Grab the lamp base and pull it toward you gently. The lamps are held snug
so a little force may be necessary to pull them out. The lamps are 16" long.
6. Install new, replacement lamps (AirGorilla #DR36-1).
a. Make sure lamp is clean – use alcohol wipe to remove dirt and fingerprints.
b. Insert UV lamp into UV lamp portal.
c. Turn swivel clamps over lamp base to hold secure.
d. Attach lamp socket (align holes in socket to lamp base pins).
7. Push the "Reset" button next to the lamp (there is a reset button for each lamp) that
restarts the 9000 hour timer that alerts you when the lamp reaches the end of its
effective life.
8. Close the Display Panel door. Plug in the power cord if applicable. Within a few
seconds, the LED lights that indicate POWER ON and AIR PURIFYING should be lit
(not the REPLACE LAMP LED).
9. If the correct LEDs are not lit, reopen the Display Panel door and make sure the lamp
socket is attached fully to the lamp base pins, then make sure the Display Panel door
is closed completely. If the LED lights are still not lit, consult the TROULESHOOTING
SECTION ABOVE.
6