ELECTRICAL & GAS CONNECTION LOCATIONS
Model 79669GO-MN
Electrical connection cable
installing the gas cooker
Gas pressures
The following table shows the supply and operating
pressures for various gases .
Gas type
Supply pressure
* If the regulator is placed upstream of the cooker inlet,
as is normal for cookers operating on LPG, then the
supply pressure and operating pressure are the same .
The following table shows the injector sizes for
each burner .
Injector orifice
Low heat burner
Medium heat burner
High heat burner
Intense heat wok burner
168mm
Gas connection point to regulator
LPG
2 .8 (kPa)
LP
0 .55mm
0 .7mm
0 .9mm
1 .0mm
Checking piping size
To work out a suitable pipe size for connection use:
The information in this table .
Gas type
79669GO-MN
Information about the length of run, number of elbows,
tees and bends, the available service pressure and the
supply requirements .
Electrical
cable entry
Gas Connection
point
Read these points before connecting to the gas supply:
• The appliance is preset LPG use . If natural gas is
to be used see Conversion to natural gas section .
• Gas installation must be made in accordance with
SANS10087-1, the local gas fitting regulations,
municipal codes and other statutory regulations .
• The gas connection point is a ½" BSP external
thread located at the rear of the appliance as shown .
• A regulator must be fitted to the appliance . Ensure
95mm
that when fitted the pressure test point of regulator
is accessible .
• The regulator is to be fitted to the appliance
connection point, then fit hard piping from the
regulator to the consumer hard piping . Ensure the
installation allows the withdrawal of the appliance .
NG
2 .0 (kPa)
NG
0 .7mm
0 .96mm
1 .19mm
1 .46mm
41
LPG
NG
1013 .3 g/h
47 .5 MJ/h