AEG 949499862 Manuel de l'utilisateur - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} AEG 949499862. AEG 949499862 28 pages.

AEG 949499862 Manuel de l'utilisateur

2. SAFETY INSTRUCTIONS

2.1 Installation
WARNING!
Only a qualified person must install this
appliance.
• Remove all the packaging.
• Do not install or use a damaged
appliance.
• Follow the installation instructions supplied
with the appliance.
• Always take care when moving the
appliance as it is heavy. Always use safety
gloves and enclosed footwear.
• Do not pull the appliance by the handle.
• Install the appliance in a safe and suitable
place that meets installation requirements.
• Keep the minimum distance from other
appliances and units.
• Before mounting the appliance, check if
the appliance door opens without restraint.
• The appliance is equipped with an electric
cooling system. It must be operated with
the electric power supply.
Cabinet minimum height
(Cabinet under the worktop
minimum height)
Cabinet width
Cabinet depth
Height of the front of the
appliance
Height of the back of the
appliance
Width of the front of the ap‐
pliance
Width of the back of the ap‐
pliance
Depth of the appliance
Built in depth of the appli‐
ance
Depth with open door
Ventilation opening mini‐
mum size. Opening placed
on the bottom rear side
2.2 Electrical connection
• All electrical connections should be made
• The appliance must be earthed.
• Make sure that the parameters on the
• Always use a correctly installed
• Do not use multi-plug adapters and
• Make sure not to cause damage to the
590 (600) mm
• Do not let mains cables touch or come
560 mm
550 (550) mm
594 mm
• The shock protection of live and insulated
576 mm
• Connect the mains plug to the mains
595 mm
559 mm
• If the mains socket is loose, do not
• Do not pull the mains cable to disconnect
569 mm
548 mm
• Use only correct isolation devices: line
1022 mm
560x20 mm
• The electrical installation must have an
Mains supply cable length.
Cable is placed in the right
corner of the back side
Mounting screws
WARNING!
Risk of fire and electric shock.
by a qualified electrician.
rating plate are compatible with the
electrical ratings of the mains power
supply.
shockproof socket.
extension cables.
mains plug and to the mains cable. Should
the mains cable need to be replaced, this
must be carried out by our Authorised
Service Centre.
near the appliance door or the niche below
the appliance, especially when it operates
or the door is hot.
parts must be fastened in such a way that
it cannot be removed without tools.
socket only at the end of the installation.
Make sure that there is access to the
mains plug after the installation.
connect the mains plug.
the appliance. Always pull the mains plug.
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
isolation device which lets you disconnect
the appliance from the mains at all poles.
1500 mm
4x25 mm
ENGLISH
5