SAFETY INSTRUCTIONS
WARNINGS Special care should be taken when operating an electrical device. To avoid possible Electric Shock or risk
to personal safety, please observe all electrical safety rules and tips. Here are some examples:
•
To prevent electric shock resulting from water back-siphoning, pump must be installed above the water level.
•
Reduce the risk of bursting by only use air handling devices rated for pressure no less than 8 psi.
•
Connect the pump only to an outlet with GFCI (see Proper Grounding).
•
Do not use this pump in the vicinity of explosive or flammable materials, liquids or gases.
•
Do not use the air pump other than to pump air.
•
Do not operate this pump if it falls into or being flood by water.
•
Do not operate this pump when there is water on parts that are not intended to be wet.
•
Do not operate this pump if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or
dropped.
•
Keep power cable away from heated surfaces.
•
To prevent any personal injury or damage to the equipment, operate the pump only in fully assembled state.
INSTALLATION NOTES
Install the pump upright securely on a dry and stable horizontal surface prior to operation. Sit pump in shaded area that
shelters from excessive weathering. Do not allow pump to swelter under intense sun or flooded by rain, and avoid places
with excessive dust or debris. The ambient operating temperature for this pump is between 41°F (5°C) and 104°F (40°C).
Operation of pump in temperature outside of the recommended temperature range may result in malfunction or severely
shorten the pump life.
For aeration applications, the pump should be installed above the water surface level. If necessary, install a reliable low air
resistance check valve to prevent water back flow or siphon when electrical power is turned off. Inspect and replace
clogged check valve regularly.
From a drip loop (U shape) for the power cable to prevent any water dripping down the line from entering the electrical
outlet, which could cause a short or electric shock.
PROPER GROUNDING In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric
current. This product is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an outlet that is
properly installed and grounded in accordance with all local codes and ordinances.
Connect the pump only to an outlet with GFCI (Ground Fault Circuit Interrupter).
This device should serve to interrupt the flow of electric current in the event of
ground faults (electrical current that unintentionally flows to ground). Check proper
operation of GFCI every month, and replace faulty GFCI immediately.
Check with a qualified electrician when the grounding instructions are not completely understood, or when in doubt as to
whether the product is properly grounded. Do not modify the plug provided; if it do not fit the outlet, have the proper outlet
installed by a qualified electrician.
If extension cord is necessary, use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle
that accepts the plug on the pump. Make sure your extension cord is not damaged. When using an extension cord, be sure
to use one heavy enough to carry the current the pump draws. For lengths less than 50 ft, No. 16/3 AWG extension cord
shall be used. An undersized cord can result in a drop in line voltage, loss of power and overheating.
GFCI Terminal
Plug with grounded pin