alkitronic CLS2/600 Manuel d'utilisation et d'entretien - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} alkitronic CLS2/600. alkitronic CLS2/600 12 pages. Compact torque multiplier
7
8
2.7
Finishing or interruption the work (even with
change of accessories)
• Interrupt the air pressure in the machine
• Disconnect the compressed air supply to the maintenance
unit or to the supply system
• By briefly switching on the machine, remove any residual air
• Decouple the compressed air hose on the machine
Beware of components exposed to high air pressure:
Unintentional operation of the alkitronic® torque
multiplier may result in injury or property damage.
When removing the compressed air hose from the
machine, always disconnect the air supply first. An
out of control compressed air hose can cause injury
or property damage.
In the event of prolonged periods without use, oil
must be supplied to the engine via the compressed
air inlet on the pistol grip. This prevents corrosion
damage to the motor lamella (see section 3.3 Main-
tenance and 4.1 Air lubrication).
3.
Service
Do not use damaged alkitronic® torque multipli-
ers and accessories. Only use original alkitronic®
spare parts / accessories.
3.1
Changing from standard nut, standard connector
and DMA (CLD, CLS, CLS2)
• Interrupt compressed air supply - uncouple the com-
pressed air hose at the machine
• Place the alkitronic® CL on a flat surface
• Remove rubber ring (6) and locking pin (7) or locking
screw (8)
• Remove standard nut / connector (2) / (3) towards the
front (Fig. 7.1)
• Pull DMA (1) out of the gearing (4) towards the front (Fig. 7.1)
• Assembly is in reverse order
Pneumatic Torque Multiplier
Fig. 6
Disc
Handle
5
6
4
alkitronic® DMA
Torque reaction absorber
3.2
Changing the alkitronic® STA (Standard adapter)
and the support plunger for type RCL
Always insert the support pin and / or standard
adapter completely, otherwise the housing can be
severely damaged during operation.
Support plunger
9
Fig. 7.1
alkitronic® STABI
Standard connector
7
8
3
2
alkitronic® STACO
Standard nut
2
5
alkitronic®
1
STACO
Standard
nut
Support plunger
alkitronic® STA
Standard adapter