Problem
Programme inactive,
EMPTY WATER (RESER-
VOIR) display illumi-
nated.
Drying cycle ends
shortly after pro-
gramme starts. END
(EINDE) display illumi-
nated.
Drying cycle lasts an
unusually long time.
Note:
After around 5 hours
the drying cycle ends
automatically (see
„Drying cycle com-
plete").
Changing bulb for inside light
Only use a special bulb which is designed specially for dryers. The spe-
cial bulb is available from the after-sales service,
ET-Nr. 112 552 000-5.
1
Warning! Do not use standard bulbs! These develop too much heat and
may damage the machine!
1
Warning! Before replacing the bulb, disconnect the mains plug; with a
permanent connection: fully unscrew or deactivate the fuse.
1. Unscrew covering bonnet from above bulb (this can be found directly
behind the loading aperture, at the top; refer to "Description of ma-
chine" section.)
2. Replace defective bulb.
3. Screw covering bonnet back down.
1
Warning! For reasons associated with safety, the covering bonnet must
be screwed down tightly. If this is not done, the dryer must not be op-
erated.
22
Possible cause
Condensate tank is full.
Not enough washing load-
ed or washing loaded is too
dry for selected programme.
Lint filter clogged.
Heat exchanger clogged
with lint.
SPECIAL CARE (LAGE TEMP.)
button pressed and load
volume too big.
Load volume too big.
Laundry insufficiently pre-
drained.
Remedy
Empty condensate tank, then
start programme with START/
PAUSE (START/PAUZE) button.
Select time programme or
higher drying level (e.g. INTEN-
SIVE DRY - INTENSIEF-DROOG
instead of STORAGE DRY -
KAST-DROOG).
Clean lint filter.
Clean heat exchanger.
SPECIAL CARE (LAGE TEMP.) is
only suitable for use with
loads of up to 3kg!
Reduce load volume.
Laundry must be adequately
pre-drained.