32. Free spin speed selection
Selection choice:
– No
The spin speed programmed into the block
is always used.
– Yes
The spin set for the last programme block
before starting a programme is used for all
programme blocks. It does not matter if
programme step "Free spin speed selection"
was set to "yes" or "no" in the last block.
33. Spin
Selection choice:
– No
Spinning does not take place.
– Automatic
Spin profile
Phase
1
2
Time
1min. 1min. 1min. 3min. 3min. 2min.
Rhythm
No
12/3
Spin speed
500
30
(rpm)
– User defined
Up to 6 different spin phases can be
programmed for each spin step.
Time
0, 1 to 59 sec
0 to 99 min.
Rhythm
No
Normal
Gentle
Gentle+
User defined 3/12 to
(*Total always 015)
Spin speed
No
Normal
Drench
User defined
20 to 70 rpm.
300 - max. rpm**
**Areas 1 to 19 and 71 to 299 rpm cannot be
selected.
M.-Nr. 06 533 430
3
4
5
6
No
No
No
12/3
500
850
max.
30
99 to 99 sec.*
The maximum spin speed available
depends on the machine:
Model
PW 6101
PW 6131
PW 6161
PW 6201
PW 6241
PW 6321
34. Repeat
A block or programme can be repeated.
Selection choice:
– No
No repeat.
– Block
Repeat programme blocks
1 x block up to 9 x blocks
– Programme
Repeat programmes
1 x programme up to 9 x programmes
35. Block end signal
If a programme block has finished a signal
can be activated.
Selection choice:
– No
A block end signal is not given.
– Yes
The "Block end" output relay is activated.
The block end signal remains active until the
End or Start button or Rotary dial are
activated.
Programming
Max. spin speed
1200 rpm
1100 rpm
1150 rpm
1100 rpm
1100 rpm
1000 rpm