ABB DODGE USN 524 Manuel - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} ABB DODGE USN 524. ABB DODGE USN 524 16 pages. Adapter mount & direct mount plummer blocks

Block
Amount Sufficient For
Size
Normal Lubrication
Liters/Min.
509
510
608/308
511
609/309
512/610/310
513
611/311
515
612/312
516
613/313
517
314
518
615/315
519/616/316
520
617/317
522/619/319
524
620/320
526
622/322
528
530
624/324
532
Table 12 - USN Circulating Oil Chart
Circulating Oil Flow*
Maximum Amount For
Heat Dissipation Due to
External Heat Source
Liters/Min.
.009
.26
.011
.341
.011
.341
.015
.378
.015
.378
.017
.454
.019
.567
.019
.567
.023
.662
.023
.662
.025
.738
.025
.738
.028
.757
.028
.757
.030
.946
.030
.946
.038
1.13
.042
1.32
.042
1.32
.057
1.59
.066
1.82
.066
1.82
.072
2.08
.072
2.08
.087
2.27
.095
2.84
.095
2.84
.113
3.03
10
Static Oil
Level (mm)
Drain Holes
Size (BSPP)
W**
26.5
24
26.5
29
32.5
28.5
32
40.5
27
30.5
38
42
34.5
37
34.5
42
47
39.5
42
45
53.5
58
57
58.5
49
51.5
60
53
1/8-28
1/8-28
1/8-28
1/8-28
1/8-28
1/8-28
1/8-28
1/8-28
1/4-19
1/4-19
1/4-19
1/4-19
3/8-19
3/8-19
3/8-19
3/8-19
3/8-19
3/8-19
3/8-19
3/8-19
1/2-14
1/2-14
1/2-14
1/2-14
1/2-14
1/2-14
1/2-14
1/2-14