procedures
All service adjustments are factory preset and should not require change unless controls and/or associated components are replaced.
140.0_V B+ voltage check
1.
Set the BRIGHT and PICTURE to minimum by using the PICTURE menu.
2.
Connect the DVM on TPD50 (D-Board by and cold ground
3.
Confirm that B+ voltage is 142V ± 6.0V. This voltage supplies B+ to the horizontal output and flyback circuits.
Source voltage chart
120V AC line input. Set the BRIGHT and the PICTURE to minimum by using the PICTURE menu. Use cold or hot ground for the (-) lead
of the DVM as needed
A-BOARD
STBY 7V (BY IC006) A-Board TPA9
MAIN 9V (BY IC006) A-Board TPA90
MAIN 5V (BY IC2856) A-Board TPA15
GC 2.5V (BY IC2856) A-Board TPA25
STBY 3.3V (BY A13 CONNECTOR) A-Board TPA16 3.3V ± 0.2V
MAIN 3.3V (BY IC 2856) A-Board TPA33
D-BOARD
+B2 (BY D14 CONNECTOR) D-Board TPD50
30V (BY IC805) D-Board TPD19
15V (BY IC802) D-Board TPD7
-15V (BY IC805) D-Board TPD6
SOUND+ (BY D6 CONNECTOR) D-Board TPD4 17.2V + 1.5V -1.0
SOUND- (BY D6 CONNECTOR) D-Board TPD53
210V (BY IC503) D-Board TPD34
MAIN 12V (BY D14 CONNECTOR) D-Board TPD22
High voltage check
http://tsn.pstc.panasonic.com/viewing/NA/CT-27HL15N/SIMP/MTNC050426A1/doc/MTN...
VOLTAGE
7.5V ± 0.75V
9.0V ± 0.5V
5.2V ± 0.3V
2.6V ± 0.2V
3.3V ± 0.2V
VOLTAGE
142.0 ± 6.0V
33.5 ± 2.0V
14.5 + 1.5V -1.0
-15.5V ± 1.5V
-18.0V ± 1.5V
211.0V ± 4.0V
12V ± 0.5V