AQUATECH ECO 3600 Instructions pour l'utilisateur - Page 2
Parcourez en ligne ou téléchargez le pdf Instructions pour l'utilisateur pour {nom_de_la_catégorie} AQUATECH ECO 3600. AQUATECH ECO 3600 12 pages. Eco pond series
IMPORTANT about SECURITY!
The installation and operation of ECO pumps may only be carried out
by persons over 16 years, who can understand the text of this users
instructions correctly.
Check that the power supply is identically with the one indicated on the pump.
ECO pumps are provided with 10 m of grounded electrical safety cable and casted
plug. The pump has to be connected to a grounded plug with earth leakage circuit
breaker of 30 mA .
Use only good quality grounded extension leads, flexes, plugs and the like.
For ensuring optimal safety, the cable is casted into the pump housing and cannot be
exchanged. If the cable is damaged, the pump may not be used any longer.
When carrying out activities in or near the water, all devices which are immersed or
in touch with the pond water should be switched off.
The pump may not be lifted or pulled by the power supply cable. Mount an additional
wire to the pump housing to lift the pump out of the water.
The ECO pump is exclusively made for pumping water. Other floating media, burn-
able liquids or water over 40º C may not be pumped.
The ECO pump may not run dry, as this could damage or even destroy the pump.
Possible damages caused by dry run are not covered by the warranty.
The ECO pump has to be installed at least 10 cm and not more than 2 m below the
water level. See the maximum depth on the data sheet of the pump.
The ECO pump has to be placed horizontal and not in the bottom sludge. If neces-
sary you should use an elevation like f. ex. a socket of bricks.
The water temperature may not exceed 40º C, as this can damage the pump. How-
ever the automatic thermal security device will ensure, that the pump will be discon-
nected.
When the pump and its connections are installed and checked completely (there may
not be any air bubbles in the ducts), it can be connected to the power supply.
NB:
Before use: Check that the cable, the socket and the plug are dry and intact.
Caused by safety reasons, repairs at the cable and the pump motor may only be carried
out by the supplier or an authorized electrician (see the certificate of warranty).
When the pump is installed outside the pond (dry-installation), all connections and con-
nection parts have to be watertight and equipped with gaskets. Fasten all connections
and connection parts properly.
The gaskets have a limited lifetime and have to be checked regularly. If the gaskets are
porous or defect, they have to be replaced.
For avoiding overheating, when the pump is installed outside the pond, the hoses /
pipes should have following diameters:
(Use always the hose / pipe with the biggest possible diameter).
ECO
3600 - 4800 min. 25 mm on outlet and 32 mm on suction side
ECO
7200 - 11000 min. 32 mm on outlet and 32 mm on suction side
ECO 14000 - 18000 min. 40 mm on outlet and 40 mm on suction side
ECO 22000 - 25000 min. 40 mm on outlet and 50 mm on suction side