Parcourez en ligne ou téléchargez le pdf Instructions pour {nom_de_la_catégorie} Alphalux SureScan ALXPIR. Alphalux SureScan ALXPIR 4 pages. 10a, 240v, 10 metre range

• Do not install sensor pointing directly into sunlight.
• Avoid installing the sensor where exposed to strong reflections such as windows and swimming pools.
• Heat sources can trigger PIR sensors. Installations close to BBQ's, chimneys, exhausts and flues should be
avoided. (Note: It is strongly recommended that the sensor be located where floodlight heat cannot trigger
the sensor).
• The installed sensor should be pointing down-wards where possible.
• To avoid false triggering by animals, direct the sensing zone above the expected height of animals.
Fig 1.
Effective
Movement
SureScan™ detects movement across a series of zones. This special feature is maximised if SureScan™ is
mounted in a position in which traffic moves obliquely through the field of detection (fig.1) instead of
moving toward the sensor (fig.2).
Sensor Head
Mounting
Screw
TYPICAL SURFACE MOUNTING INSTALLATION DIAGRAM
Note: Additional sealing may be required to create the required weather rating
Fig 2.
10m
10m
Less Effective
Movement
Terminal
Cover
Wall Plugs
where
required
(drill hole
0 6mm)
Rubber Seal
DIMENSIONS:
Mounting Surface
Note: SureScan™ shown fitted to mounting box as supplied
71mm
53mm (Straight)
154mm
30mm
18mm