S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
S A F E T Y F U N C T I O N (see enclosed
brochure)
The desired maximum temperature for example
max. 42°C can be pre-set thanks to the safety
function.
A S S E M B L Y (see page 04)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
A D J U S T M E N T (see page 08)
After the installation, the output temperature of
the thermostat must be checked. A correction is
necessary if the temperature measured at the
output differs from the temperature set on the
thermostat.
D I M E N S I O N S (see page 09)
F L O W D I A G R A M (see page 09)
 Hand shower
 Bath Spout
S P A R E P A R T S (see page 15)
XX = Colors
00 = Chrome Plated
67 = Matt Black
C L E A N I N G (see page 12)
O P E R A T I O N (see page 10)
M A I N T E N A N C E
To guarantee the smooth running of the
thermostat, it is necessary from time to time to turn
the thermostat from total hot to total cold.
M A I N T E N A N C E S E C U F L E X H O S E
(see page 16)
Repeat cleaning when pull out becomes difficult.
M A I N T E N A N C E C H E C K V A L V E
(see page 16)
The check valves must be checked regularly
according to EN 806-5 in accordance with
national or regional regulations (at least once a
year).
0 3