S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower may only be used for bathing, hygiene and
body cleaning purposes.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ During installation of the product by qualified trained
personnel, make sure that the entire fastening surface is
even and smooth (no protruding seams or tile offset),
that the finish of the wall is suitable to apply the product
and has no weak points.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure
35286XX7 ⁄ 35308XX7:
35301XX7 ⁄ 35316XX7:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
F A U L T
⁄ Head shower extremely leaky
⁄ Shower drips continuously
⁄ Water drips from showerhead a short
time after the valve is closed
⁄ Sprays not operating properly
A S S E M B L Y (see page 04)
max. 0,6 MPa
0,29 - 0,4 MPa
0,15 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Head shower soiled ⁄ scaled
⁄ Shut-off unit damaged
⁄ Normal clearing of pipes
⁄ Flow pressure too low
⁄ Filters are dirty
⁄ Head shower soiled ⁄ scaled
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 07)
F L O W D I A G R A M
(see page 08)
I N S T A L L A T I O N E X A M P L E
i
(see page 08)
C L E A N I N G (see page 10)
S P A R E P A R T S (see page 15)
O P E R A T I O N (see page 16)
R E M E D Y
⁄ Clean ⁄ descale head shower
(see page 10)
⁄ Exchange shut-off unit
⁄ Check water pressure (If a pump has
been installed check to see if the
pump is working).
⁄ Increase water pressure
⁄ Clean filters (see page 12)
⁄ Clean ⁄ descale head shower
(see page 10)
0 3