Axxeron HESCH HE 5710 Manuel d'utilisation - Page 18

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Axxeron HESCH HE 5710. Axxeron HESCH HE 5710 19 pages. Solenoid valve controller

6.

Setting

Number of valves
The number of valves is determined automatically by the controller. Detected valves are
indicated by lit LEDs.
Number of full cleaning cycles
Set the number of cycles (1...9) via the rotary coding switch CYCLES. If the rotary coding
switch is on 0, the cyclic cleaning is deactivated. The cleaning process for the set cycles is
started via the trigger signal at the terminals START CYCLE (+ and -).
Pulse time of valves
Setting via the potentiometer PULSE between 0.02 and 1.2 seconds.
Pause time of valves
Setting via the potentiometer PAUSE between 1 and 270 seconds.
18
HE 5710 / 5711 Operating Instructions
# 371814 | Version 1.4