INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR
ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS
D. Shutdown
1.
While squeezing the trigger of the spray gun, turn the manually operated steam line valve off in order to remove
the steam line pressure and allow the unit to cool as much as possible before shutdown.
2.
Release the trigger of the spray gun and turn the manually operated water valve fully off.
DANGER: Do not proceed with any maintenance unless the washdown
station has been relieved of all pressure, has been allowed to reach ambient
temperature, and has been drained or purged of all fluids. Failure to do so
can cause serious personal injury to personnel.
V.
MAINTENANCE
Use only qualified experienced personnel who are familiar with this equipment and thoroughly understand all the
instructions in this manual for all maintenance.
A. Preventive Maintenance
Create maintenance schedules, safety manuals and inspection details for each washdown station.
On all installations, regularly check the following items for purposes of maintenance.
1.
Washdown station components, for corrosion and to remove debris build-up.
2.
Piping and fittings, for corrosion and to remove debris build-up.
3.
All connections, to maintain tightness and eliminate leaks.
4.
Outlet temperature, to maintain desired setting.
5.
Water & Steam line strainer, to remove debris build-up.
6.
Hose and spray gun, for damage or wear.
7.
Stream trap, for proper operation.
8.
Mounting connections, for tightness.
By evaluating your own operating experience, develop an appropriate maintenance schedule necessary for the
specific application. Realistic maintenance schedules can only be determined with full knowledge of the services and
application situation involved.
DANGER
7
Installation: 1004 Rev 4
Issued: February 7, 2013