Pan/Tilt control
Address
Data
F0F00884
82000ddd
F0F00888
82000ddd
Optical Filter control
Address
Data
F0F0088C
882000ddd
GPIO control
Address
Data
F0F20400
0000000d
F0F20404
Sets Pan manually.
Sets Tilt manually.
For black and white models,
selects 3 × 3 filter.
For color models, changes the
Bayer pattern.
The Bayer output pattern
changes by shifting one pixel
at the image output starting
position from right to left and/
or up or down.
Bayer array patterns
Pattern 0
G
B
R
G
Pattern 1
B
G
G
R
Pattern 2
R
G
G
B
Pattern 3
G
R
B
G
Outputs a signal to the output
port.
Selectable values are 0 to 3.
Reads out the status of the
input port.
Readable values are 0 to 3.
Strobe control
Address
Data
F0F20200
80000000
82000000
82dddwww
The formula for absolute value
shutter control register address
Absolute value shutter control CSR offset
address
Address
Data
F0F0071C
003C025C
The register address for absolute value shutter control is
given by the following formula.
F0000000h + 003C025Ch
Address
Data
F0F00970
3727C5AC
F0F00974
418C0000
F0F00978
The data is indicated by 32-bit floating-point format.
3727C5AC is 0.00001, and 418C0000 is 16.
A strobe signal is not output.
Outputs an exposure signal.
ddd = delay, www = signal
width, unit = µs.
Absolute value shutter control
CSR offset.
4 = F0F00970h
×
Absolute value shutter control
minimum value. (ReadOnly)
Absolute value shutter control
maximum value. (ReadOnly)
Absolute value shutter control
setting value.
25