SSC Redundancy LED States
SSC Redundancy LED States
The Redundancy LED on the SSC indicates that software is loaded on the card, but it is serving as a standby
component. SSC support 1:1 redundancy; the Redundancy LED should be green on the other SSC for normal
system operation.
The possible states for this LED are described in the following table. If the LED is not green, use the
troubleshooting information in the table to diagnose the problem.
Table 18: SSC Redundancy LED States
Color
Green
Amber
Blinking Amber
None
SSC System Status LED States
The System Status LED on the SSC indicates the that there is a loss of service somewhere in the system. If
this LED is red, the system requires maintenance or service (for example, the system could not locate a a valid
software image at boot-up, or a high temperature condition exists).
The possible states for this LED are described in the following table. If the LED is not green, use the
troubleshooting information also provided to diagnose the problem.
Table 19: SSC System Status LED States 11
Color
Green
Red
Troubleshooting
18
Description
Card is in standby mode
Card is not backed up by the standby SSC.
Tasks or processes being migrated from the
active SSC to the standby SSC.
Card is not receiving power.
OR
Card has failed.
Description
System is operating normally
The system has experienced a loss of
service.
Troubleshooting
Troubleshooting
None needed. The other SSC should be in
Standby mode.
Check the status of the other SSC. If one it
has failed or has been removed from the
chassis, the system can continue to function
but redundancy is compromised.
Refer to Monitoring the System for
information on determining the status of
the SSC and system software processes.
Refer to Monitoring the System for
information on determining the status of
the SSC and system software processes.
Verify that the Run/Fail LED is green. If
so, the card is receiving power and POST
results are positive. If it is off, refer to the
SSC Run/Fail LED States section for
troubleshooting information.
Troubleshooting
None required.
Refer to Monitoring the System for
information on determining the status of
system hardware and software processes.