Removing the E-Series Server from a Cisco ISR 4451-X
This section includes the following topics:
•
•
•
Shutting Down the E-Series Server Installed in a Cisco ISR 4451-X
SUMMARY STEPS
1.
2.
3.
DETAILED STEPS
Command or Action
Step 1
enable
Example:
Router> enable
slot
Step 2
ucse subslot
Example:
Router# ucse subslot 1/0 shutdown
Step 3
hw-module subslot
Example:
Router# hw-module subslot 1/0 oir-stop
SM Hardware slot 0 can be removed
Restarting the E-Series Server Installed in a Cisco ISR 4451-X
If the oir-stop command was issued and the E-Series Server was not physically removed from the slot,
you can restart the E-Series Server with the oir-start command. From a console terminal, issue the
hw-module subslot slot/0 oir-start command. The console displays the module's changing state.
Example:
Router# hw-module subslot 1/0 oir-start
OL-26447-03
Shutting Down the E-Series Server Installed in a Cisco ISR 4451-X, page 31
Restarting the E-Series Server Installed in a Cisco ISR 4451-X, page 31
Inserting the E-Series Server in a Cisco ISR 4451-X, page 32
enable
ucse subslot slot/0 shutdown
hw-module subslot slot/0 oir-stop
/0 shutdown
slot
/0 oir-stop
Purpose
Enables privileged EXEC mode.
Enter your password if prompted.
Shuts down the E-Series Server gracefully.
Before proceeding with the next command, verify
Note
that the E-Series Server has shut down. When the
E-Series Server shuts down, the power LED turns
orange. You can also use CIMC to verify if the
E-Series Server has powered down.
Shuts down power to the specified E-Series Server to
prepare it for removal.
When it is safe to remove the E-Series Server, a message is
displayed as shown in the example.
Note
Before removing the E-Series Server, verify that
power to the slot is shut down. The power LED
should be off.