5. Mark Hole Locations
Lift the range hood into place and insert the mounting bracket
tabs through the slots in the back of the range hood.
Hold the range hood firmly in place with one hand and
bend each mounting tab (A) upward approximately 90°.
Mark the hole at the power supply knockout (B).
OPTIONAL: Mark the hole in each mounting tab.
Remove the range hood and set it aside.
A
90˚
B
6. Drill Electrical Opening
Using a 1
/
" (3 cm) drill bit, drill the hole in the dot
1
4
marked previously at the electrical strain relief.
OPTIONAL: Using a
/
" (3 mm) drill bit, drill pilot holes
1
8
for the dots marked previously at each mounting tab
at an approximate 45° angle in an upward direction.
7. Prepare Range Hood Vents
and Mounting Tabs
A
Install Strain Relief
■
Install a UL Listed/CSA Approved
strain relief (A).
Mounting Tabs
■
Start a #8-18 x
/
" (4.2 x 16 mm) truss-head screw into
5
8
the mounting tab (D) on each side of the range hood
as shown in the inset. Insert the screws approximately
2 turns into the mounting tab holes.
Non-vent (Recirculating) Installations
■
Remove the (2) T10 Torx
front rectangular vent cover (B).
†
TORX is a registered trademark of Acument Intellectual Properties, LLC.
®
C
x2
B
/
" (13 mm)
1
2
screws and remove the top,
®†
7