8.2. InspirAIR
®
Top 450
Supplier brand
Designation
References
Energy class - Average climate
Average climate - SEC - Specific energy consumption (kWh/(m
Cold climate - SEC - Specific energy consumption (kWh/(m
Warm climate - SEC - Specific energy consumption (kWh/(m
Declared type
Type of airflow
Type of motor installed or planned
Type of heat recovery system
Thermal efficiency of heat recovery (%)
3
Maximum RVU (m
/h)
Electric power absorbed at Qmax (W)
LwA - Sound power level (dB)
3
Reference airflow (m
/s)
Difference in reference pressure (Pa)
3
SPI (W/(m
/h)
Control factor (%)
Type of control system
Maximum declared internal leakage rate under negative
pressure for BVU (%)
Maximum declared external leakage rate under negative
pressure for UVU and BVU (%)
Maximum declared internal leakage rate under positive pressure
for BVU (%)
Maximum declared external leakage rate under positive pressure
for UVU and BVU (%)
Mixing rate for standalone BVU without branch connections (%)
Position of visual alarm
Description of visual alarm
Regular replacement of filters to ensure unit performance and
energy efficiency
Instructions for installation of fresh air inlets
Sensitivity of airflow to pressure variations at +20 Pa
Sensitivity of airflow to pressure variations at -20 Pa
Indoor/outdoor air tightness (m
Annual electricity consumption - AEC (kWh electricity/a)
Average climate - AHS - Annual heating savings (kWh primary
energy/a)
Cold climate - AHS - Annual heating savings (kWh primary
energy/a year)
Warm climate - AHS - Annual heating savings (kWh primary
energy/a year)
2
a)
2
3
/h)
Aldes
®
InspirAIR
Top 450
Classic
11023476
A
2
a)
-36,70
-74,37
a)
-12,49
RVU
Bidirectional ventilation
unit
4/ Variable speed
Recuperation
88
470
218
57
0,091
50
0,25
1
Manual control
1
1
0,5
0,6
NA
cf. notice
cf. notice
cf. notice
NA
NA
NA
NA
333
4502
8808
2036
28
Aldes
®
InspirAIR
Top 450
InspirAIR
Premium
PREMIUM ERV
11023478
A
-36,03
-74,16
-11,55
RVU
Bidirectional ventilation
Bidirectional ventilation
unit
4/ Variable speed
4/ Variable speed
Recuperation
89
470
244
53
0,091
50
0,29
1
Manual control
Manual control
1
1
0,5
0,6
NA
cf. notice
cf. notice
cf. notice
NA
NA
NA
NA
379
4550
8901
2057
Aldes
®
Top 450
11023478
B
-32,10
-66,88
-9,55
RVU
unit
Recuperation
78
480
255
53
0,088
50
0,30
1
1
1
0,5
0,6
NA
cf. notice
cf. notice
cf. notice
NA
NA
NA
NA
396
4200
8216
1899