Zanussi ZF711W Livret d'instructions - Page 15

Parcourez en ligne ou téléchargez le pdf Livret d'instructions pour {nom_de_la_catégorie} Zanussi ZF711W. Zanussi ZF711W 20 pages. Zanussi instruction freezer zf711w

Climate
for an ambient temperature of
classification
SN
N
ST
T

Electrical connection

Any electrical work required to install this
appliance should be carried out by a
qualified electrician or competent person.
This appliance must be earthed.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1362) fuse
must be used.
Should the plug need to be replaced for any reason.
The wires in the mains lead are coloured in
accordance with the following code:
Green and yellow
-Earth
Blue
-Neutral
Brown
-Live
The wire coloured green and yellow must be
+10°C to +32°C
+16°C to +32°C
+18°C to +38°C
+18°C to +43°C
If the cabinet is placed in a corner and the side with
the hinges facing the wall, the distance between the
wall and the cabinet must be at least 10 mm to allow
the door to open enough so that the baskets can be
removed.
connected to the terminal marked with the letter "E"
or by the earth symbol
yellow.
The wire coloured blue must be connected to the
terminal marked "N" or coloured black
The wire coloured brown must be connected to the
terminal marked "L" or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
15
or coloured green and
Zanussi 818 15 02--03/3