Do not operate this meter with an antifreeze and water mixture.
Meter will not register properly.
Meter model 3579 is designed to measure a variety of fluids that
include engine oils, diesel oils and hydraulic oils.
The meter is totally electronic except for the oval gear metering
mechanism. The electronic register is powered by two 1-1/2 Volt AAA
alkaline batteries.
The meter can be programmed to register in:
• pints, quarts, or gallons, and totalize in gallons
• liters and totalize in liters
NOTE: The meter is factory programmed to register in
quarts and totalize in gallons.
A liquid-crystal display shows the following amounts of fluid
dispensed by volume:
• Current delivery
• RESET TOTAL (momentary)
• TOTAL
All three amounts display with a floating decimal point.
• Current delivery (0.000 to 99999)
• RESET TOTAL and TOTAL (0.0 to 999999)
The meter's non-volatile memory retains the unit of measure, totals,
and calibration factor during battery replacement.
Operation
To zero the current delivery and RESET TOTAL the meter must be
in Standby. See Figure 1.
Press the Reset button to zero the current delivery.
When the RESET TOTAL is required to be reset:
1. Press the Reset button.
• The RESET TOTAL displays for 5 seconds.
2. Press and hold the Reset button while the RESET TOTAL displays.
• The RESET TOTAL is reset to zero.
The RESET TOTAL and TOTAL update automatically during fluid
delivery.
Max. Operating
Storage
Pressure
Temperature
psi
bar
° F
1000
70
-4 to 158 -20 to 70
* With SAE 10W Oil at 68° F (20° C)
This document contains confidential information that is the property of Alemite, LLC
670955
and is not to be copied, used, or disclosed to others without express written permission.
Service Guide
Electronic Meter
CAUTION
Operating
Temperature
° C
° F
° C
23 to 122
-5 to 50
Table 1 Electronic Meter Model 3579 Specifications
167 Roweland Drive, Johnson City, Tennessee 37601
www.alemite.com
Copyright
Model
393792-6
Programmable Units of Measure Flow Rate in Units / Min.
Current
pint
quart
gallon
liter
Figure 1 Electronic Meter Model 3579
Accuracy* Repeatability*
± 1%
1%
3.7 x 4.2 x 3.1
Alemite, LLC
©
2010 by Alemite, LLC
393792-6
Thread Type
3759-
3/4" NPT
3/4" GAS
Totalizer
Min.
gallon
1.5 gallons
liter
6 liters
Dimensions (w/ Guard)
L x W x H
in.
cm
9.4 x 10.7 x 7.9
Revision (3-10)
3579
Max.
16 gallons
60 liters
Weight
lbs
kg
1.46
0.6
SER 3579