The air dryers of the AD-series dispose of a hygrostat for setting the required
humidity value. This hygrostat is located in the operation panel of the unit.
It makes that the air dryer cuts in as soon as the ambient humidity exceeds the
preset value. If the humidity value falls below the set value, the hygrostat will switch
off the unit.
The hygrostat is placed in the operation panel laterally at the unit.
Pos. 0
= Unit is switched off
Pos. 1
= Continues operation
80-100% = The dehumidifier switches off
when a humidity of approx.
80 - 95% r.h. has achieved.
And switches on again when
humidity is higher than 80-95%.
60 - 80% = The dehumidifier switches
off when a humidity of approx.
60 - 80% r.h. has achieved.
And switches on again when
humidity is higher than 60-80%.
40 - 60% = The dehumidifier switches off when a humidity of approx. 40 - 60% r.h.
has achieved. And switches on again when humidity is higher than 40-60%.
20 - 40% = The dehumidifier switches off when a humidity of approx. 20 - 40% r.h.
has achieved. And switches on again when humidity is higher than 20-40%.
The smooth setting option of the hygrostat makes a very convenient humidity
control possible for you. If very precise values are requested, you should match the
hygrostat with the information on a precise hygrometer.
Please consider:
Humidity values of a minimum of 40 % - 45 % r.h. can be achieved with a
condensation dryer. An adsorption dryer is to be employed if lower values are
required.
For this purpose, ask your technical consultant.
Optimal climate:
For living rooms, environmental conditions of 20° -25° C and 50 - 60 % r.h. are
recommended.
For building drying, the hygrostat becomes turned at continues running (POS. I).
In the case of the drying rooms with wood equipment (e.g. floors) or paintings,
antiques and similar things should not be fallen below a humidity of 55%.
Ask your technical consultant in the case of special applications.