Fog Machine H-2VD
4.1.2. DMX table
If the device is controlled with a DMX signal, the display shows the set DMX
address.
Kanal
Wert von
0
1
10
4.1.3. Fluid Sensor
This machine has a software-based fluid sensor that is designed to protect the
pump from damage. Turn on the "Fluid Sensor" to activate the "NO FLUID"
protection function.
4.1.4. Activate the No-Fluid sensor
As soon as the Fluid Sensor is switched ON, the software based "NO FLUID"
protection function is activated. If the program detects that the pump is no
longer pumping fluid, the pump switches off automatically and draws
attention to the problem with a warning message on the display.
4.1.5. Reset the "NO FLUID" warning
After the machine initiated the "NO FLUID" protection function, after refilling
the fluid, there are three ways to reset the warning.
• Hold down the "Enter" key until the pump is again supplied with fluid. In
this case, the machine starts to emit fog again.
• In DMX mode, drag the DMX channel assigned to the machine on the
lighting console down to the value 0. Then drag the channel to the
highest value (255).
• Turn off the "FLUID SENSOR" in the menu.